Clim'Up MUSE Outdoor Unit, 4.1 - 12 kW

MUSE outdoor units are equipped with a ROTARY DC INVERTER compressor, a 4-way valve for reversing heating/cooling mode, and a modulating fan.

They are designed to be combined with 1,2,3,4 or 5 indoor units (UME, UCE, UGE or UCARE) (the relevant specifications are qvqilqble to download and in the table of recommendations below).

  • Packaging: 1 package
  • WiFi function
  • R32 fluid
  • Optimal comfort all year round
  • Big choice of external unit
  • Option to add up to 5 indoor units on the same outdoor unit


 

            MUSE

40-2

50-2

60-3

80-3

100-4

120-5

 

Output in cooling mode (min./max.)

kW

4.1 (1.8-4.51)

5.3 (2.0-5.83)

6.2 (2.2-6.71)

7.9 (2.3-8.69)

10.5 (2.5-11.00)

12.00 (2.77-12.7)

 

Output in heating mode (min./max.)

kW

4.8 (2.05-5.28)

5.6 (2.21-6.16)

6.6 (2.39-7.26)

8.2 (2.45-9.02)

11.00 (2.67-11.20)

13.00 (2.96-12.80)

 

Output in cooling mode

BTU/hr

14000

18000

21200

27000

35800

41000

 

Output in heating mode

BTU/hr

16400

19100

22500

28000

37500

44400

 

Electrical power consumption in cooling mode at nominal output

kW

1.24

1.75

1.92

2.46

3.92

4.32

 

Electrical power consumption in heating mode at nominal output

kW

1.15

1.54

1.78

2.27

3.04

3.75

 

Max. air flow (outdoor unit)

m3/h

2300

2300

3100

3100

4000

4200

 

SEER

 

6.2

7.1

6.5

6.3

6.1

6.1

 

 

A++

A++

A++

A++

A++

A++

 

SCOP

 

4.1

4.1

4.4

4.0

4.0

4.0

 

 

A+

A+

A+

A+

A+

A+

 

Acoustic pressure of outdoor unit

dB[A]

54

55

56

58

61

61

 

Acoustic power of outdoor unit

dB[A]

61

62

65

65

68

68

 

Outdoor unit weight

kg

34

36

44

46

74

75

 

Refrigerant connections (Fluid - Gas)

pouces

1/4" - 3/8"

1/4" - 3/8"

1/4" - 3/8"

1/4" - 3/8"

1/4" - 3/8"

1/4" - 3/8"

 

Total max. length between indoor and outdoor units

m

40

40

60

60

80

80

 

Max. length between indoor and outdoor units

m

25

25

30

30

35

35

 

Max. height difference between indoor and outdoor units

m

15

15

15

15

15

15

 

Max. height difference between all indoor and outdoor units

m

10

10

10

10

10

10

 

Preloaded length

m

15

15

22.5

22.5

30

37.5

 

Additional load of F32 refrigerant per additional meter

g / m

20

20

20

20

20

20

 

Nominal charge of R32 refrigerant fluid

kg

0.92

0.95

1.1

1.05

2.3

2.3

 

Voltage/Frequency values

V / Hz

220-240 / 50

220-240 / 50

220-240 / 50

220-240 / 50

220-240 / 50

220-240 / 50

 

Nominal current in cooling mode

A

5.4

7.6

8.3

10.7

18.7

20.6

 

Maximum current

A

10

11

13

16

22.5

24.5

 

Power cable cross-section

mm2

3G1.5

3G1.5

3G1.5

3G2.5

3G4.0

3G4.0

 

Circuit breaker

 

C16A

C16A

C16A

C20A

C25A

C25A

 

Cross-section of cable connecting the indoor and outdoor units

mm2

4G1.5

4G1.5

4G1.5

4G2.5

4G2.5

4G2.5

 

Clear All