Ideal for hospitals, office buildings and residential blocks as well as other industrial heating system. UT-L ideally suitable for use as a reserve and peak load boiler within power stations and combined heat and power plants.
UT-H are local and district heating generation, all sectors of business, the processing industry, heat suppliers and public facilities. Used as base load, peak load and reserve heating boilers at district heating plants.
When you set up a user account with our website, the order process is quicker and you can enjoy the many functions of your account,
including your wishlist. With your customer account, you can also check the status of your order, and much more.
When you set up a user account with our website, the order process is quicker and you can enjoy the many functions of your account,
including your wishlist. With your customer account, you can also check the status of your order, and much more.
https://www.hevac.ie/p/bosch--hot-water/hboschhwHBOSCHHWBOSCH HOT WATERhttps://www.hevac.ie/v4/0940aa0c-5421-4a9b-840d-c9a2ae5d95bb/images/product_images/HBOSCHHW-600_600.jpg 0.00EURInStock/Brands<p><span style="font-size: 19.2px; font-weight: bold; line-height: 1.4em;">Hot Water Boiler</span></p>
<ul style="list-style-type: disc;">
<li>
<h2>Uni 3000 F Hot Water Boiler</h2>
</li>
<li>Type 3000 F</li>
<li>Heat transfer medium Low-pressure hot water</li>
<li>Design Reverse Flame technology</li>
<li>Output 420 to 1850 kW</li>
<li>Safety pressure up to 6 bar</li>
<li>Max. temperature to 105 °C</li>
<li>Fuel Oil, Gas</li>
<li><span>Suited to systems requiring a peak load boiler, such as district heatingschemes, that can incorporate a condenmsing base load boiler or CHP module.</span></li>
</ul>
<ul style="list-style-type: disc;">
<li>
<h2>UNIMAT Hot Water Boiler <strong>UT-L</strong></h2>
</li>
<li>Type UNIMAT UT-L</li>
<li>Heat transfer medium Low-pressure hot water</li>
<li>Design Three-pass flame tube/smoke tube technology</li>
<li>Output 650 to 19,200 kW</li>
<li>Safety pressure up to 16 bar</li>
<li>Max. temperature to 120 °C</li>
<li>Fuel Gas, Oil</li>
<li><span style="font-size: 12.8px; line-height: 1.4em;">Ideal for hospitals, office buildings and residential blocks as well as other industrial heating system. UT-L ideally suitable for use as a reserve and peak load boiler within power stations and combined heat and power plants.</span></li>
</ul>
<ul style="list-style-type: disc;">
<li>
<h2>UNIMAT Hot Water Boiler <strong>UT-M</strong></h2>
</li>
<li>Type UNIMAT UT-M</li>
<li>Heat transfer medium High-pressure hot water</li>
<li>Design Three-pass single-flame tube/smoke tube technology</li>
<li>Output 750 to 19,200 kW</li>
<li>Safety pressure up to 16 bar</li>
<li>Max. temperature to 190 °C</li>
<li>Fuel Oil, Gas </li>
<li><span style="font-size: 12.8px; line-height: 1.4em;">Exceptional performance is most evident in central heating systems for district and local community heating. </span></li>
</ul>
<ul style="list-style-type: disc;">
<li>
<h2>UNIMAT Hot Water Boiler <strong>UT-H</strong></h2>
</li>
<li>Type UNIMAT UT-H</li>
<li>Heat transfer medium High-pressure hot water</li>
<li>Design Three-pass single-flame tube/smoke tube technology</li>
<li>Output 820 to 18,300 kW</li>
<li>Safety pressure up to 30 bar</li>
<li>Max. temperature to 240 °C</li>
<li>Fuel Oil, Gas</li>
<li><span style="font-size: 12.8px; line-height: 1.4em;">UT-H are local and district heating generation, all sectors of business, the processing industry, heat suppliers and public facilities. Used as base load, peak load and reserve heating boilers at district heating plants.</span></li>
</ul>
<ul style="list-style-type: disc;">
<li>
<h2>UNIMAT Hot Water Boiler <strong>UT-HZ</strong></h2>
</li>
<li>Type UNIMAT UT-HZ</li>
<li>Heat transfer medium High-pressure hot water</li>
<li>Design Three-pass double-flame tube/smoke tube technology</li>
<li>Output 13,000 to 38,000 kW</li>
<li>Safety pressure up to 30 bar</li>
<li>Max. temperature to 240 °C</li>
<li>Fuel Oil, Gas</li>
<li><span style="font-size: 12.8px; line-height: 1.4em;">Deployed in all areas where very large amounts of heat are required, i.e. district heating generation and the processing industry.</span></li>
</ul>
<p> </p>BOSCHEUR