HDDCLIMUPEMSM

Clim'Up EMSM 20,25,35,50,70, 2.2 - 7 kW

Mono-split air-to-air heat pump for air conditioning.

Equipped with DC Inverter technology, and reversible mode, comprising an indoor unit (UME) and an outdoor unit (MOSE).

The outdoor unit is equipped with a ROTARY DC INVERTER compressor, a 4-way valve (for reversing heating/cooling mode), a modulating fan, using R32 refrigerant fluid.
The indoor unit is equipped with a variable-speed fan enabling air diffusion in 4 directions and up to 15?m. Its condensate and refrigeration connections can be located on the left- or right-hand side

It features 5 operating modes:

  • Auto,
  • Cooling,
  • Heating,
  • Dehumidifying,
  • Ventilation;

it also incorporates the following functions:

  • Night,
  • Self-clean,
  • Eco,
  • Turbo,
  • Draught protection

It can also be operated from a distance remotely using the programmable infra-red remote control (supplied as an option)

  • Packaging: 2 packages
  • WiFi function
  • R32 fluid
  • Acoustic comfort: 20?dB[A]
  • Optimal comfort all year round
  • Indoor unit compatible for mono and multisplit


 

            EMSM

20

25

35

50

70

 

Output in cooling mode (min./max.)

kW

2.20 (1.00-2.90)

2.55 (1.00-3.30)

3.60 (1.20-3.80)

5.30 (1.90-5.50)

7.03 (2.90-7.30)

 

Output in heating mode (min./max.)

kW

2.35 (1.10-3.00)

2.65 (1.10-3.30)

3.70 (1.00-3.80)

5.40 (1.40-5.60)

7.05 (2.10-8.00)

 

Output in cooling mode

BTU/hr

7500

8700

12200

18000

24000

 

Output in heating mode

BTU/hr

8000

9000

12600

18400

24000

 

Electrical power consumption in cooling mode at nominal output

kW

0.67

0.78

1.10

1.65

2.195

 

Electrical power consumption in heating mode at nominal output

kW

0.64

0.72

1.02

1.50

1.96

 

Max. air flow (HS, MS, LS *) (indoor unit)

m3/h

650/450/395

650/450/395

650/450/395

1000/860/688

1150/950/750

 

Max. air flow (outdoor unit)

m3/h

1800

1800

1800

2700

3200

 

SEER

 

6.1

6.5

6.1

6.5

6.3

 

 

A++

A++

A++

A++

A++

 

SCOP

 

4.1

4.2

4.2

4.0

4.3

 

 

A+

A+

A+

A+

A+

 

Min./max. acoustic pressure of indoor unit

dB[A]

20 / 40

20 / 41

20 / 42

20 / 48

20 / 49

 

Acoustic power of indoor unit

dB[A]

52

53

53

58

59

 

Min./max. acoustic pressure of outdoor unit

dB[A]

50

50

50

53

53

 

Acoustic power of outdoor unit

dB[A]

60

60

58

62

64

 

Outdoor/indoor unit weight

kg

9 / 25

9 / 27

9 / 27

12.5 / 35

15 / 45

 

Refrigerant connections (Fluid - Gas)

pouces

1/4" - 3/8"

1/4" - 3/8"

1/4" - 3/8"

1/4" - 1/2"

1/4" - 5/8"

 

Min./Max. length between indoor and outdoor units

m

3/20

3/20

3/20

3/25

3/25

 

Max. height difference between indoor and outdoor units

m

10

10

10

15

15

 

Max. preloaded piping length between indoor and outdoor units

m

7

7

7

7

7

 

Additional load of F32 refrigerant per additional meter

g

15

15

15

25

30

 

Nominal charge of R32 refrigerant fluid

kg

0.53

0.58

0.68

1.28

1.44

 

Voltage/Frequency values

V / Hz

220-240 / 50

220-240 / 50

220-240 / 50

220-240 / 50

220-240 / 50

 

Nominal current in cooling mode

A

3.00

3.40

4.90

7.36

10.30

 

Maximum current

A

8

8

9.5

12

16

 

Max. power comsumption

kW

1.5

1.5

1.9

2.9

3.7

 

Power cable cross-section

mm2

3G1.5

3G1.5

3G1.5

3G1.5

3G2.5

 

Circuit breaker

 

C16A

C16A

C16A

C16A

C20A

 

Cross-section of cable connecting the indoor and outdoor units

mm2

5G1.5

5G1.5

5G1.5

5G1.5

5G2.5

 

Clear All